Link to NASA Agency Website
NASA-NEPP Logo - Click to return to the NEPP Home Page    + View the NASA Portal
NEPP Website Search  
Powered By Google
Link to the NEPAG Home Page Link to the Photonics Page Link to the NEPP Parts Page Link to the NEPP Packaging Page Link to the NEPP Radiation Page Link to the DC/DC Converters Page Link to the NASA Parts Selection List
Link to the NASA Technical Standards Server Link to the NASA Workmanship Website Link to the Wirebond Website Link to the Tin Whiskers Home Page Link to the Plastic Encapsulated Microcircuits Page Link to the NEPP Publications Search Link to the NEPP Experts Page Link to the NEPP Calendar
Your Path: Home » Focused Portals » PEMs Portal » NEPAG PEMs Evaluation Information
  PEMs Overview Docs
  PEMs Guidelines Docs
  PEMs Test Techniques Docs
  NASA PEMs Test Data
  PEMs Other Documents
  PEMs Information and Links: Non-NASA
NEPAG PEMs Evaluation Information
  Search
 
 
 
 
NEPAG PEMs Evaluation

NASA's use of Commercial-off-the-Shelf (COTS) Plastic Encapsulated Microcircuits (PEMs) electronic components in Space applications has raised serious concerns and issues about their inherent reliability, quality and design performance robustness.  To fully understand, to assess and to mitigate risks, NASA is undertaking a thorough investigation and extensive screening and packaging evaluations on various COTS components from selected manufacturers.

This website provides background information about this investigation and the published results.  For more information about this effort, contact Mike Sampson or Mike Sandor. Link to PROJECT OVERVIEW

Bookmarks for this page:

Test Flow (starting at the top)

Die Oriented Qualification Tests

Package Sample Qualification

Package Moisture Resistance

Results

High Speed Op-Amp

Precision Voltage Reference

Packaging Moisture Resistance Final Report

MSL Evaluation Results

MSL and Moisture Resistance Test Results

CSAM Data for the Multiplexer

Other Supporting Documents including:

Activation Energy Calculator

Reliability of Low Tg in COTS PEMs for Space

Moisture Test Terminology Compared

DRAFT COTS PEMs Guideline Document

The following is an example of the Test Flow used in the evaluation:

Step

Screen

Required

Reject Criteria

Special Instructions

1

DPA

1. SEM / Cross section of steps,via, contacts 2. Xray  Fien Focus 3. Glass transition temperature for plastic package(2 ea/date code). Ref: Mil-Std-1580B

Any abnormal processing especially with metalization. Thinning, voids, notches, or apparent abberations will be recorded.

 

2

Serialization

Laser Serialization or other means for traceability

 

 

3

1st Electricals

+25°C, 70°C, 0°C, test to data sheet, Read & Record

 

Calculate/Compare Vendors AOQL from rejects.

3A

FITS Verification Sample Static B/I

1000 Hr. 125ºC B/I, +25°C, 70°C, 0°C with functional subgroups, R&R at 168 hrs, 500 hrs, 1000 hrs

B/I conditions for devices with Top-max < 125ºC:

105°C: 105ºC for 2300 hrs   85ºC:  85ºC for 2620 hrs

 

4

Temp Cycle

-65°C to 150°C

10 cycles ; Mil-Std-883 method 1010 Cond C

 

5

X-ray

MIL-STD-883, Method 2012

Inspect for wire sweep (top view)

 

6

C-SAM

Inspect for delamination and or cracks between LF & MC, die surface to MC, die attach to die pad, die pad to MC.

Delamination, voids, or cracks: >10% of area. Rejects will be identified and recorded. Photographs will be reviewed by the Specialist

 

7

Electricals

+85°C, +125°C, -40°C, -55°C, test to datasheet

Any part failing to meet data sheet parametrics at  the temperatures specified. Data to be recorded/reviewed for outliers.

Bag and tag/ remove hard failures

8

Dynamic Burn-In

168 hours @ +125°C, Vcc = max rating

B/I conditions for devices with Top-max < 125ºC:

105°C: 105ºC for 400 hrs   85ºC:  85ºC for 440 hrs

Junction temp <25C below Tg.

Parts to be bagged and tagged

9

Electricals

+25°C, +70°C, +85°C, +125°C, -40°C, -55°C with functionality

Data to be recorded/reviewed for outliers/drifters

 

10a

Screening Data Analysis & Formatting

 

 

 

10b

Screening Data Engineering Review/QCI Sample Selection

 

 

 

 

Die Oriented Qualification Sampling Tests

 

11

Dynamic Burn-In Life Test

1000 hr., 125ºC

Life test conditions for devices with Top-max < 125ºC:

105°C: 105ºC for 2300 hrs   85ºC:  85ºC for 2620 hrs

Junction temp <25C below Tg.

12

End Point Electricals

+25°C, +70°C, +85°C, +125°C, -40°C, -55°C, test to datasheet

Any part failing to meet data sheet parametrics at  the temperatures specified. Data to be recorded/reviewed for outliers/drifters

Do interim R/R at 250 & 500 hrs for 1000 hr life.  Do interim R/R at 500, 1000 and 1500 hr for 2000+  hr life test.

13

DPA

Die visual inspection/Bonding inspection at die pad and lead frame

 

Photo documentation required. Perform destructive bond pull on virgin & screened samples for each date code, 5 pcs per date code (3 min).   Sniff for Bromine and Phosphorous released agents.

 

Package Oriented Qualification Sampling Tests

 

14

Lead Solder Heat Exposure

1st Half of Samples:

Surface

Mount Heat Exposure

Ref JESD22-A113-B

Applicable Steps:

Para 3.1.2

Para 3.1.4

Para 3.1.6 VPR only

2nd Half of Samples:

Resistance to Soldering Heat Exposure

Ref JESD22-B106-B

Notes: para 4.2;Solder bath will be 315C+or-10C

Hermeticity tests are not applicable to PEMs

All parts must be accepted for mark permanency before commencing with Group D testing.

14A

Post Electricals

25ºC, test to data sheet

 

 

15

Temp Cycle Qual

Ta = -65ºC to +150ºC

1000 cycles; Mil-Std-883 method 1010, Cond C

 

16

Post Temp Cycle Electricals

+25°C, +85°C, +70°C, +125°C, -40°C, -55°C, test to data sheet

Data to be recorded and statistically compiled

Do interim R/R at 500, and 700 cylces. Perform 100% CSAM and  do DPA on 4 pcs  upon completion

17

HAST Qualification

130C/85% RH, JESD22-A110-B, 96 hrs

 

For part type with 85ºC Top-max, lot is spilt  (11 and 11 pcs).  Conditions for 1st lot is 110ºC/85% RH for 264 hrs.   Conditions for 2nd lot is 130ºC/85% RH for 96 hrs.

18

Post HAST Electricals

+25°C, 85°C, 0°C, +125°C, -40°C, -55°C, test to data sheet

Data to be recorded, within 48 hrs of ramp-down, and statistically compiled

Perform 100% CSAM and  do DPA on 4 pieces upon completion.

19

Vibration

MIL-STD-883, Method 2007, Cond. A (20 g’s)

 

 

19A

Post Electricals

Test to data sheet at 25ºC

 

 

20

Cold Startup

8 hr soak, minimum at -55ºC, unbiased

 

Test at nominal Vcc supply for functionality (in situ at    -55ºC).  Test at 25ºC to data sheet with R&R

 

Package Moisture Evaluation

 

1

CSAM

Topside, backside, thruscan

 

 

2

Flux/Pretinning

Using Sn/Pb

Water soluble flux used

 

3

Temperature Cycling

JESD22-A113-B

 

 

4

Bake

100ºC, 24 hrs

Intended to remove moisture

 

5

Moisture Sensitivity Test

MSL 1 or 3

Moisture level selected is per the mfr’s guarantee

Volt Diff Amplifier was level 3, all other devices were level 1 

 

Subflow for type of soldering environment (22 pieces through each subflow 6a, 6b and 6c).  All parts saw all subflows Except, Op-Amp, Analog MUX and Volt Reference did not go through the 6b flow.

 

6a

Hand Soldering

Each lead exposed to heat for 5 sec max, tip temp = 335ºC max

 

 

6b

IR/Convection

Ref JESD22-A113-B, 245 - 250ºC max

 

 

6c