Step
|
Screen
|
Required
|
Reject Criteria
|
Special Instructions
|
|
1
|
DPA
|
1. SEM / Cross section of steps,via, contacts 2. Xray Fien Focus 3. Glass transition temperature for plastic package(2 ea/date code). Ref: Mil-Std-1580B
|
Any abnormal processing especially with metalization. Thinning, voids, notches, or apparent abberations will be recorded.
|
|
|
2
|
Serialization
|
Laser Serialization or other means for traceability
|
|
|
|
3
|
1st Electricals
|
+25°C, 70°C, 0°C, test to data sheet, Read & Record
|
|
Calculate/Compare Vendors AOQL from rejects.
|
|
3A
|
FITS Verification Sample Static B/I
|
1000 Hr. 125ºC B/I, +25°C, 70°C, 0°C with functional subgroups, R&R at 168 hrs, 500 hrs, 1000 hrs
|
B/I conditions for devices with Top-max < 125ºC:
105°C: 105ºC for 2300 hrs 85ºC: 85ºC for 2620 hrs
|
|
|
4
|
Temp Cycle
|
-65°C to 150°C
|
10 cycles ; Mil-Std-883 method 1010 Cond C
|
|
|
5
|
X-ray
|
MIL-STD-883, Method 2012
|
Inspect for wire sweep (top view)
|
|
|
6
|
C-SAM
|
Inspect for delamination and or cracks between LF & MC, die surface to MC, die attach to die pad, die pad to MC.
|
Delamination, voids, or cracks: >10% of area. Rejects will be identified and recorded. Photographs will be reviewed by the Specialist
|
|
|
7
|
Electricals
|
+85°C, +125°C, -40°C, -55°C, test to datasheet
|
Any part failing to meet data sheet parametrics at the temperatures specified. Data to be recorded/reviewed for outliers.
|
Bag and tag/ remove hard failures
|
|
8
|
Dynamic Burn-In
|
168 hours @ +125°C, Vcc = max rating
|
B/I conditions for devices with Top-max < 125ºC:
105°C: 105ºC for 400 hrs 85ºC: 85ºC for 440 hrs
|
Junction temp <25C below Tg.
Parts to be bagged and tagged
|
|
9
|
Electricals
|
+25°C, +70°C, +85°C, +125°C, -40°C, -55°C with functionality
|
Data to be recorded/reviewed for outliers/drifters
|
|
|
10a
|
Screening Data Analysis & Formatting
|
|
|
|
|
10b
|
Screening Data Engineering Review/QCI Sample Selection
|
|
|
|
|
Die Oriented Qualification Sampling Tests
|
|
11
|
Dynamic Burn-In Life Test
|
1000 hr., 125ºC
|
Life test conditions for devices with Top-max < 125ºC:
105°C: 105ºC for 2300 hrs 85ºC: 85ºC for 2620 hrs
|
Junction temp <25C below Tg.
|
|
12
|
End Point Electricals
|
+25°C, +70°C, +85°C, +125°C, -40°C, -55°C, test to datasheet
|
Any part failing to meet data sheet parametrics at the temperatures specified. Data to be recorded/reviewed for outliers/drifters
|
Do interim R/R at 250 & 500 hrs for 1000 hr life. Do interim R/R at 500, 1000 and 1500 hr for 2000+ hr life test.
|
|
13
|
DPA
|
Die visual inspection/Bonding inspection at die pad and lead frame
|
|
Photo documentation required. Perform destructive bond pull on virgin & screened samples for each date code, 5 pcs per date code (3 min). Sniff for Bromine and Phosphorous released agents.
|
|
Package Oriented Qualification Sampling Tests
|
|
14
|
Lead Solder Heat Exposure
|
1st Half of Samples:
Surface
Mount
Heat
Exposure
Ref JESD22-A113-B
Applicable Steps:
Para
3.1.2
Para
3.1.4
Para
3.1.6 VPR only
|
2nd Half of Samples:
Resistance to Soldering Heat Exposure
Ref JESD22-B106-B
Notes: para 4.2;Solder bath will be 315C+or-10C
Hermeticity tests are not applicable to PEMs
|
All parts must be accepted for mark permanency before commencing with Group D testing.
|
|
14A
|
Post Electricals
|
25ºC, test to data sheet
|
|
|
|
15
|
Temp Cycle Qual
|
Ta = -65ºC to +150ºC
|
1000 cycles; Mil-Std-883 method 1010, Cond C
|
|
|
16
|
Post Temp Cycle Electricals
|
+25°C, +85°C, +70°C, +125°C, -40°C, -55°C, test to data sheet
|
Data to be recorded and statistically compiled
|
Do interim R/R at 500, and 700 cylces. Perform 100% CSAM and do DPA on 4 pcs upon completion
|
|
17
|
HAST Qualification
|
130C/85% RH, JESD22-A110-B, 96 hrs
|
|
For part type with 85ºC Top-max, lot is spilt (11 and 11 pcs). Conditions for 1st lot is 110ºC/85% RH for 264 hrs. Conditions for 2nd lot is 130ºC/85% RH for 96 hrs.
|
|
18
|
Post HAST Electricals
|
+25°C, 85°C, 0°C, +125°C, -40°C, -55°C, test to data sheet
|
Data to be recorded, within 48 hrs of ramp-down, and statistically compiled
|
Perform 100% CSAM and do DPA on 4 pieces upon completion.
|
|
19
|
Vibration
|
MIL-STD-883, Method 2007, Cond. A (20 g’s)
|
|
|
|
19A
|
Post Electricals
|
Test to data sheet at 25ºC
|
|
|
|
20
|
Cold Startup
|
8 hr soak, minimum at -55ºC, unbiased
|
|
Test at nominal Vcc supply for functionality (in situ at -55ºC). Test at 25ºC to data sheet with R&R
|
|
Package Moisture Evaluation
|
|
1
|
CSAM
|
Topside, backside, thruscan
|
|
|
|
2
|
Flux/Pretinning
|
Using Sn/Pb
|
Water soluble flux used
|
|
|
3
|
Temperature Cycling
|
JESD22-A113-B
|
|
|
|
4
|
Bake
|
100ºC, 24 hrs
|
Intended to remove moisture
|
|
|
5
|
Moisture Sensitivity Test
|
MSL 1 or 3
|
Moisture level selected is per the mfr’s guarantee
|
Volt Diff Amplifier was level 3, all other devices were level 1
|
|
Subflow for type of soldering environment (22 pieces through each subflow 6a, 6b and 6c). All parts saw all subflows Except, Op-Amp, Analog MUX and Volt Reference did not go through the 6b flow.
|
|
6a
|
Hand Soldering
|
Each lead exposed to heat for 5 sec max, tip temp = 335ºC max
|
|
|
|
6b
|
IR/Convection
|
Ref JESD22-A113-B, 245 - 250ºC max
|
|
|
|
6c
|
|