Process Wafer Fabrication |
Grade 1 Class S QML V |
Grade 2, Jan Class B, QML Q |
Grade 3 883B |
Grade 4 Commercial |
Comments |
Agency Team Certification of Plant and Operators |
Yes |
Yes |
No |
No |
Does Fab meet good engineering practices. Is same fab (or contract fab)? |
Baselined Process Flow |
Yes |
Yes |
No |
No |
Vendor’s 883B flow may change as frequently as they want/need. No JPL control. |
Traceability of Baseline Changes |
Yes |
Yes |
No |
No |
883B = As long as meets data sheet, no explanation required; and Data sheet can change at will. |
Number of Wafer Runs in lot |
1 |
No longer controlled (but only from certified fab) |
|
|
883B may use as many as they want, from different fabrication facilities, domestic or foreign - and mix together, change at will. Major radiation and DPA concern! |
Wafer Lot Acceptance |
Yes |
No |
No |
No |
B product, wafer thickness, metal thickness, glass thickness, gold backing thickness, and thermal stability not monitored. These were "early" indicators of ionic contamination, latent failures, etc. |
Wafer Rework Control |
Yes |
Yes |
Not controlled |
No |
A concern for homogeneity and radiation hardness assurance |
Wafer Bonusing Controlled |
Yes |
No |
No |
No |
A concern for homogeneity and radiation hardness assurance |
Assembly |
Grade 1 Class S QML V |
Grade 2, Jan Class B, QML Q |
Grade 3 883B |
Grade 4 Commercial |
Comments |
Agency Team Certification of Plant and Operators |
Yes |
Yes |
No |
No |
883B Assembles to internal controls, changes when they desire, contracts assembly out to cost effective sources, worldwide and mixes lots |
Internal Visual Inspection |
Yes Cond. A |
Yes Cond. B |
No=Mil Spec Yes=Internal Vendor Spec |
Not done |
Rejects to Grade 2 (Cond B) Parts are acceptable to 883B flow. |
Tightened Lot Control (MIL-STD-976) |
1 |
|
|
|
883B allows for multiple operators/machines, contract to outside assembly houses [uncertified: foreign or domestic] |
Destructive Die Shear Monitor |
2 hours |
4 hours |
No |
No |
883B = Vendor spec |
Destructive Bond Pull Monitor |
2 hours |
4 hours |
No |
No |
883B = Vendor spec |
Non Destructive Bond Pull |
Yes |
No |
No |
No |
Early indicator of bonding problems prior to seal/burn-in temperatures. (Commercial product uses gold wire on aluminum metalization). New bonders have NDBP built in. |
Screening |
Grade 1 Class S QML V |
Grade 2, Jan Class B, QML Q |
Grade 3 883B |
Grade 4 Commercial |
Comments |
Agency Team Certification of Plant and Operators |
Yes |
Yes |
No |
No |
883B may change electricals, burn-in boards, testers, handlers, etc. at will. Screening can be contracted out to lower cost outside and foreign screening house and mixed. |
Electrical Subgroup 1-12 Tested |
Yes |
No |
No |
No |
S only includes read and record, Slash Sheet vs. advertised data sheet |
Extended Burn-In (Dynamic, 240 hours) |
Yes |
No |
No |
None |
883B = Control of BI Board configuration may be changed at will. |
100% PIND Test |
Yes |
No |
No |
No |
Particles are a concern in Space hardware. |
PDA |
5% |
10% |
Some |
No |
Reject lots from Class S are acceptable for B. |
Attributes Data |
Yes |
Yes |
Yes |
No |
|
Variable Data (Read/Record) |
Yes |
No |
No |
No |
S only |
Failure Analysis Requirements |
Yes |
No |
No |
No |
S only |
Qualification |
Grade 1 Class S QML V |
Grade 2, Jan Class B, QML Q |
Grade 3 883B |
Grade 4 Commercial |
Comments |
Agency Team Certification of Plant and Operators |
Yes |
Yes |
No |
No |
883B Qualification can be conducted by foreign or domestic contract house, to published or changed electricals, vendor’s life test burn in boards. |
Frequency of 1000 hour Life test |
Yes (every lot)
|
12 months |
12 months |
None |
S = on every lot, Class B & 883B = may be completed by outside contractor, and may be completed on a "similar device". May be several years between actual qualification. < /FONT > < /FONT > < /FONT > |
Frequency of Package Qual |
6 months |
12 months |
12 months |
None |
883B = May be completed by outside contractor. |