APPLICATION NOTES FOR MIL-PRF-123
|
The
NPSL application notes for multilayer ceramic capacitors were being amended
(May 2013) to reflect the following recommendations from a NASA Engineering
& Safety Center (NESC) report [1] on the subject of low
voltage failure phenomenon of ceramic capacitors: R-1. NASA guidelines should be amended to remove any
requirements to perform Humidity Steady-State Low Voltage (HSSLV) test as an
add-on lot acceptance test for MIL QPL MLCCs. R-3. NASA guidelines should be amended to remove restrictions
on MLCCs rated at less than 100 V when used in low voltage applications. Reference: [1]
“Multilayer Ceramic Capacitors (MLCC) –Low Voltage Failure (LVF)
Phenomenon” NASA/TM-2010-216852,
NESC-RP-07-056, October 2010, NASA Engineering and Safety Center (NESC) |
For
historical reference, application notes that have been rescinded may be viewed
here