Specification
Number
|
Current Specification
Revision Date
|
Summary of
Current Pure Tin
Prohibition
|
Revision when
Pure Tin Prohibition Language was Added
|
|
|
|
|
Capacitors
|
|
|
|
|
MIL-PRF-20
(Ceramic)
|
05/06/93
Rev H Am 2
|
Pure
tin is allowed on terminals |
|
MIL-PRF-123
(Ceramic)
|
07/06/98
Rev B Am 5
|
Pure
tin is allowed on chip capacitor terminations only |
|
MIL-PRF-23269
(Glass)
|
08/06/93
Rev E Am 1
|
No
pure tin allowed. Minimum of 3% lead. |
08/06/93
Rev E Am 1
|
MIL-PRF-39003
(Tantalum)
|
05/22/98
Rev H Am 4
|
No
pure tin allowed. Minimum of 3% lead. |
08/06/93
Rev H Am 2
|
MIL-PRF-39006
(Tantalum)
|
07/07/98
Rev E Am 1
|
No
pure tin allowed on terminals. However, spec does not prevent tin
plated cases. |
12/24/93
Rev D Am 1
|
MIL-PRF-39014
(Ceramic)
|
09/16/97
Rev F
|
No
pure tin allowed. Minimum of 3% lead. |
11/23/93
Rev E Am 4
|
MIL-PRF-49467
(Ceramic)
|
07/15/98
Rev A Am 2
|
No
pure tin allowed. Minimum of 3% lead. |
05/19/97
Rev A
|
MIL-PRF-49470
(Ceramic)
|
07/15/98
Am 1
|
No
pure tin allowed. Minimum of 3% lead. |
11/19/97
Base
|
MIL-PRF-55365
(Tantalum)
|
04/13/98
Rev D Am 1
|
No
pure tin allowed. Minimum of 3% lead. |
08/02/93
Rev C Am 4
|
MIL-PRF-55681
(Ceramic)
|
06/29/98
Rev E Am 1
|
Pure
tin is allowed. |
07/13/94
Rev D
|
MIL-PRF-83421
(Film)
|
12/30/93
Rev B Am 3
|
No
pure tin allowed. Minimum of 3% lead. |
07/04/93
Rev B
|
MIL-PRF-87217
(Film)
|
02/23/94
Am 4
|
Pure
tin is not expressly disallowed. See MIL-PRF-83421. |
|
|
|
|
|
Connectors
|
|
|
|
|
MSFC 40M38277
|
04/23/91
|
Pure
tin finish is required for type NLS3H solder mount connectors only.
Passivated stainless steel or nickel over aluminum is used on all
other connectors. All contacts are gold plated. |
|
MSFC 40M38298
|
03/15/9
|
Pure
tin is required for the shell of type NBS3H hermetic connectors and
for the soldercups of type NBS0H and NBS3H hermetic connectors.
All other connectors are nickel coated. Contacts and engagement
surfaces of hermetic connector contacts are gold plated. |
|
MSFC 40M39569
|
06/30/83
|
Pure
tin is required for type NB3H solder mount connector shell only.
All other connectors are passivated stainless steel or nickel coated
aluminum. All contacts are gold plated. |
|
GSFC S-311-P-4
|
09/05/91
Rev D
|
No
pure tin allowed. Connectors and contacts are gold plated. |
|
GSFC S-311-P-10
|
09/21/92
Rev D
|
No
pure tin allowed. Connectors and contacts are gold plated. |
|
GSFC S-311-P-718
|
9/05/91
Base Rev
|
No
pure tin is used on connectors or contacts. Connector shells are nickel
plated or chemically treated. Contacts are gold plated. |
|
MIL-C-5015
|
03/15/94
Rev G Am 5
|
No
pure tin is used on connectors or contacts. Soldercup contacts
are pretinned with Sn60 tin-lead solder inside the solder well. |
|
MIL-PRF-24308
|
11/12/97
Rev D Am 2
|
Pure
tin is required on Class H (Hermetic) shells and contact bodies.
Latest revision of MIL-PRF-23408/9 is not clear on material and finish
for space. Page 1 and 2 are in conflict. ; Page 1 lists
Class K while page 2 lists Class M non-magnetic. Previous revision
listed space grade to be Class K. |
|
MIL-C-26482
|
01/03/91
Rev G Am 5
|
Pure
tin is required for Series 1 and 2 hermetic seal connectors.
Series 1 solder type contacts are also pure tin plated. |
|
MIL-PRF-83513
|
04/22/97
Rev D
|
No
pure tin is used. Space grade connectors are coated with electroless
nickel. |
|
MIL-PRF-39012
|
08/25/95
Rev D Am 1
|
No
pure tin is used. Beryllium copper connectors are gold plated.
Stainless steel connectors are passivated. Contacts are gold
plated on all surfaces. |
|
MIL-C-83517
|
07/07/98
Am 4
|
No
pure tin is used. Solder type contacts are gold plated.
Connector body is stainless steel. Finish is passivated or gold
plated. Contact is gold plated. |
|
MIL-C-38999
|
04/06/90
Rev J
|
Pure
tin is required for Series I and II hermetic seal connectors only.
Solder contacts for hermetic connectors are gold plated.
The current
unreleased Rev K draft includes a pure tin prohibition with 3% lead
minimum.
|
|
MIL-C-39029
|
05/02/88
Rev E
|
No
pure tin is allowed. Solderless wrap termination areas and certain
solder terminated contacts are pre-tinned with tin-lead alloy |
|
MIL-C-55302
|
04/09/86
Rev E
|
No
pure tin is allowed. Solder contact termination end plating
is tin-lead (50-70%) composition. |
|
MIL-C-85049
|
08/30/90
Rev A
|
No
pure tin is used. |
|
|
|
|
|
Crystals
|
|
|
|
|
MIL-O-55310
|
03/25/98
Rev D
|
No
pure tin allowed. Minimum of 3% lead. |
03/15/94
Rev C
|
|
|
|
|
Discrete
Semiconductors (Diodes/Transistors)
|
|
|
|
|
MIL-S-19500
|
09/08/97
Rev K Am 1
|
No
pure tin allowed. Minimum of 3% lead. |
04/15/94
Rev J
|
|
|
|
|
Filters
|
|
|
|
|
MIL-PRF-15733
|
11/15/96
Rev G Am 5
|
No
pure tin allowed. Minimum of 3% lead. |
12/31/93
Rev G Am 4
|
MIL-PRF-28861
|
09/11/98
Rev B Am 4
|
No
pure tin allowed. Minimum of 3% lead. |
01/31/94
Rev B
|
|
|
|
|
Fuses
|
|
|
|
|
MIL-PRF-23419
(Fuses)
|
06/12/98
Rev E Am 3
|
No
pure tin allowed. Minimum of 3% lead. |
06/01/94
Rev E Am 1
|
MIL-PRF-39019
(Circuit Breakers)
|
08/27/97
Rev D
|
No
pure tin prohibition language. |
|
|
|
|
|
Inductors
|
|
|
|
|
MIL-C-39010
|
08/27/97
Rev E
|
No
pure tin allowed. Minimum of 3% lead. |
01/04/94
Rev D
|
MIL-C-83446
|
10/03/94
Rev B Am 4
|
No
pure tin allowed. Minimum of 3% lead. |
10/03/94
Rev B Am 4
|
MIL-STD-981
|
02/10/94
Rev B
|
Solder
is not allowed to be pure tin. However, no min lead content
is specified |
02/10/94
Rev B
|
|
|
|
|
Microcircuits
|
|
|
|
|
MIL-M-38510
|
08/27/93
Rev J Notice 1
|
No
pure tin prohibition language. |
|
MIL-PRF-38534
|
09/12/96
Rev C Am 1
|
No
pure tin allowed on terminations. Minimum of 2% lead. No language
about package plating restrictions |
08/23/95
Rev C
|
MIL-PRF-38535
|
12/01/97
Rev E
|
No
pure tin allowed. |
03/14/95
Rev C
|
|
|
|
|
Relays
|
|
|
|
|
MIL-PRF-6106
|
12/01/97
Rev K
|
No
pure tin allowed. Minimum of 3% lead. |
12/01/97
Rev K
|
MIL-PRF-39016
|
06/30/98
Rev E Am 2
|
No
pure tin allowed. Minimum of 3% lead. |
07/18/94
Rev E
|
MIL-PRF-83536
|
12/19/97
Rev A Am 1
|
No
pure tin allowed. Minimum of 3% lead. |
03/21/97
Rev A
|
|
|
|
|
Resistors
|
|
|
|
|
GSFC S-311-P-672
|
04/06/98
Rev E
|
Information
not available at time of table prep. |
|
GSFC S-311-P-683
|
07/02/96
Rev A
|
Information
not available at time of table prep. |
|
GSFC S-311-P-742
|
12/26/95
Rev C
|
Information
not available at time of table prep. |
|
MIL-PRF-39005
(Wirewound)
|
03/16/98
Rev E Am 1
|
No
pure tin allowed. Minimum of 3% lead. |
07/01/93
Rev D Am 2
|
MIL-PRF-39007
(Wirewound)
|
07/03/97
Rev H
|
No
pure tin allowed. Minimum of 3% lead. |
03/23/93
Rev G Am 1
|
MIL-PRF-39008
(Carbon Comp)
|
04/11/97
Rev C Notice 1
Inactivated
|
No
pure tin allowed. Minimum of 3% lead. |
05/05/93
Rev C Am 1
|
MIL-PRF-39009
(Wirewound)
|
07/03/97
Rev D
|
A
“Note” in Section 6 “prohibits” pure tin but does not specify a min
lead content. Terminals require minimum of 40% lead. |
01/27/94
Rev C Am 1
|
MIL-PRF-39015
(Variable)
|
06/09/98
Rev D Am 1
|
No
pure tin allowed. Minimum of 3% lead. |
04/27/93
Rev C Am 2
|
MIL-PRF-39017
(Film)
|
05/19/97
Rev F
|
No
pure tin allowed. Minimum of 3% lead. |
07/01/93
Rev E Am 2
|
MIL-PRF-55182
(Film)
|
09/17/98
Rev G Am 3
|
No
pure tin allowed. Minimum of 3% lead. |
08/11/93
Rev F Am 2
|
MIL-PRF-55342
(Film)
|
09/17/98
Rev G Am 1
|
No
pure tin allowed. Minimum of 3% lead. |
05/10/93
Rev E Am 2
|
MIL-PRF-83401
(Network)
|
03/18/96
Rev G
|
No
pure tin allowed. Minimum of 3% lead. |
06/11/93
Rev F Am 3
|
MIL-PRF-914
(Network)
|
12/19/97
Rev A Am 1
|
No
pure tin allowed. Minimum of 3% lead. |
|
|
|
|
|
Thermistors
|
|
|
|
|
MIL-T-23648
|
06/15/98
Rev D Am 1
|
No
pure tin allowed. Minimum of 3% lead. |
04/15/93
Rev C Am 1
|
GSFC S-311-P-18
|
05/12/95
Rev G
|
No
pure tin prohibition language. |
|
|
|
|
|
Transformers
|
|
|
|
|
MIL-T-27
|
06/06/94
Rev E Am 2
|
No
prohibition in base spec. |
|
MIL-STD-981
|
02/10/94
Rev B
|
Solder
is not allowed to be pure tin. However, no min lead content
is specified. |
02/10/94
Rev B
|
|
|
|
|
Wire
and Cable
|
|
|
|
|
S-311-P-13
|
06/07/96
Rev B
|
Pure
tin is required for all wire
Pure tin coated
wire is recommended for solder applications only. Tin whisker
growth is only a risk in areas where the insulation has been removed
and the wire has not been coated with solder.
|
|
MIL-C-17
|
01/08/96
Rev G Am 3
|
Pure
tin is required for the outer conductor of certain dash numbers of
semi-rigid copper clad cable. There is no impact on standard
part numbers used by NASA. |
|
J-W-1177
|
10/16/96
Rev B Notice 1
|
Tin
coating is not permitted. The superseding document NEMA MW-1000
does not permit tin plating. |
|
MIL-W-22759
|
05/07/91
Rev E Am 1
|
Pure
tin plating is allowed on some styles including (but not limited to)
/16, /18, /32, /34. |
|
MIL-W-81381
|
09/08/87
Rev A Notice 1
|
Pure
tin is required for detail specifications /21 and /22 only.
Pure tin coated
wire is recommended for solder applications only. Tin whisker
growth is only a risk in areas where the insulation has been removed
and the wire has not been coated with solder.
|
|
QQ-W-343
(Bus Wire)
|
04/18/97
Rev G
|
No
pure tin prohibition language |
|
MIL-DTL-27500
|
12/10/97
Rev H
|
Pure
tin is required for shield styles T, V, J and D |
|